Operational modes: |
Direct bus connection to ECoSlink. Operation with ECoS or Central Station Reloaded V3.0.0. is possible. |
Feedback section: |
16 feedback modules. |
|
Configurable by using jumpers as digital inputs (e.g. for contact tracks or reed switches) or as track occupancy detectors (current sensor). |
|
Galvanical isolation of feedback modules and command station |
|
Max. 3A current load per feedback input |
RailCom®: |
4 of 16 feedback sections can be used as RailCom feedback sections ("local detector"), if desired. Recognition of loco address |
Dimensions: |
86mm x 86mm x 25mm (3.39 x 3.39 x 0.98 inch) |
Included in delivery: |
ECoSDetector feedback module, terminals, ECoSlink bus connection cable, extensive instruction manual |
|
|
|
ECoSDetector Standard |
Operational modes: |
Directly connected to ECoSlink bus. Operation with ECoS command station and Central Station Reloaded V3.0.0 possible. |
Feedback section: |
16 feedback modules as digital inputs (e.g. for contact tracks or reed switches). Galvanical isolation of feedback modules and command station. |
Dimensions: |
86mm x 86mm x 25mm (3.39 x 3.39 x 0.98 inch) |
Included in delivery: |
ECoSDetector Standard feedback module, terminals, ECoSlink bus connection cable, extensive instruction manual |
|
|
|
ECoSDetector RC |
Operational modes: |
Directly connected to ECoSlink bus. Operation with ECoS command station and Central Station Reloaded V3.0.0 possible. |
Feedback section: |
4 feedback inputs configured as track occupancy detectors (current sensor). Galvanical isolation of feedback modules and command station. |
RailCom®: |
4 feedback sections can be used as RailCom feedback sections ("local detector"). Recognition of loco address |
Dimensions: |
86mm x 86mm x 25mm (3.39 x 3.39 x 0.98 inch) |
Included in delivery: |
ECoSDetector RC feedback module, terminals, ECoSlink bus connection cable, extensive instruction manual |
|
|
|
ECoSDetector Extension |
Operational modes: |
Extension module for ECoSDector, is powered and controlled by it. Transistor outputs are powered externally. |
Outputs: |
32 transistor outputs, 100mA output load each. Construction as „open collector“ is connected to ground |
|
Total current of all outputs is max. 1.5A |
Dimensions: |
86mm x 86mm x 25mm (3.39 x 3.39 x 0.98 inch) |
Included in delivery: |
ECoSDetector Extension module, terminals, extensive instruction manual |