Further information

Technical data - ECoSDetector feedback modules

  ECoSDetector
Operational modes: Direct bus connection to ECoSlink. Operation with ECoS or Central Station Reloaded V3.0.0. is possible.
Feedback section: 16 feedback modules.
  Configurable by using jumpers as digital inputs (e.g. for contact tracks or reed switches) or as track occupancy detectors (current sensor).
  Galvanical isolation of feedback modules and command station
  Max. 3A current load per feedback input
RailCom®: 4 of 16 feedback sections can be used as RailCom feedback sections ("local detector"), if desired. Recognition of loco address
Dimensions: 86mm x 86mm x 25mm (3.39 x 3.39 x 0.98 inch)
Included in delivery: ECoSDetector feedback module, terminals, ECoSlink bus connection cable, extensive instruction manual
   
  ECoSDetector Standard
Operational modes: Directly connected to ECoSlink bus. Operation with ECoS command station and Central Station Reloaded V3.0.0 possible.
Feedback section: 16 feedback modules as digital inputs (e.g. for contact tracks or reed switches). Galvanical isolation of feedback modules and command station.
Dimensions: 86mm x 86mm x 25mm (3.39 x 3.39 x 0.98 inch)
Included in delivery: ECoSDetector Standard feedback module, terminals, ECoSlink bus connection cable, extensive instruction manual
   
  ECoSDetector RC
Operational modes: Directly connected to ECoSlink bus. Operation with ECoS command station and Central Station Reloaded V3.0.0 possible.
Feedback section: 4 feedback inputs configured as track occupancy detectors (current sensor). Galvanical isolation of feedback modules and command station.
RailCom®: 4 feedback sections can be used as RailCom feedback sections ("local detector"). Recognition of loco address
Dimensions: 86mm x 86mm x 25mm (3.39 x 3.39 x 0.98 inch)
Included in delivery: ECoSDetector RC feedback module, terminals, ECoSlink bus connection cable, extensive instruction manual
   
  ECoSDetector Extension
Operational modes: Extension module for ECoSDector, is powered and controlled by it. Transistor outputs are powered externally.
Outputs: 32 transistor outputs, 100mA output load each. Construction as „open collector“ is connected to ground
  Total current of all outputs is max. 1.5A
Dimensions: 86mm x 86mm x 25mm (3.39 x 3.39 x 0.98 inch)
Included in delivery: ECoSDetector Extension module, terminals, extensive instruction manual