Bulletin: *EMD 16cyl 567BC (FT)*

*EMD 16cyl 567BC (FT)*

Equipped with ESU "FULL THROTTLE" features!
MUST use LokProgrammer Version 4.4.21 or newer

The EMD 567 16cyl Prime Mover was one of the most widely used Prime Movers in the world! From F-Units to Geeps this popular power house can still be found in many locomotives riding the rails today.

We have provided 2 versions of the prime mover in the sound file.

With Transition and without Manual Transition!

Transition is the process by which the transmission of a diesel-electric locomoitve is brought from series wiring to parallel wiring. When in series, all current in the locomotive pass through all motors: this produces maximum low-speed force in the motors, i.e., maximum starting torque. When in parallel, current is divided among the motors: this produces maximum high-end efficency, i.e., highest motor speed. In the Early EMD 567 prime movers this could be done manually. There was a throttle lever and a transition lever on the control stands. When the engineer made transition there was a very distinct sounds of the prime mover winding down to idle then up again quickly from Idle to the throttle notch. Not all locomotives can make transition -- yard locomotives are often wired only for series. Also many locomotives were equipped with automatic transitions that occured at a high rate of speed. This classic sound of "Manual Transition" is not heard in these engines the same way as it is in the early 567s. In Fact, it is best to check your prototype as this manual transistion sound could arguably be stated to be wrong for more than it is right for! Due to this fact we have made our sound with the ability to switch between these options so you can have the proper prime mover sounds for your prototype. By simply changing 1 CV (CV 48) you can choose one or the other.

As with All Select sound files this contains up to 16 different Horns, including so newly edited ones!

This LokSound Select file contains two versions of the prime mover:
Prime mover #1 (CV48=0) features a "EMD 567BC 16cyl with Normal Transition"
Prime mover #2 (CV48=16) features a "EMD 567BC 16cyl with Manual"

Locomotives:
FP7
FP9
FL9
FT
F2
F3
F7
F9
GP7
GP8
GP9
GP10
GP11
BL2
GP18
GP28
SD7
SD9
SD18
SD28

New FULL THROTTLE features:
Drive Hold: Sound Slot 2 Mapped to F9
Independent Brake: Sound Slot 11 Mapped to F10
Run 8: Sound Slot 20 (not Mapped)
Coast: Sound Slot 21 (not Mapped)

For more info please see the "Full Throttle" Quick Start Guide in the ESU Instruction Manual Section of our Website.
http://www.esu.eu/en/downloads/instruction-manuals/digital-decoders/

Key Function Soundslots Volume CVs Volume value
LightDirectional Headlights
F1Bell428350
F2Playable Airhorn3275128
F3Coupler5291128
F4Dynamic Brake629990
F5AUX3 (Rotary Beacon)
F6AUX1 + AUX2 (Front Ditchlights)
F7Switching Mode
F8Sound (On/Off)1259128
F9Drive Hold2267128
F10Independent Brake1133920
F11Radiator (Fan) Sound831550
F12Dimmer (Headlights)
F13AUX4 (Rear Ditchlights)
F14N/A
F15Fast Spitter Valve1537150
F16Spitters on Shutdown1839550
F17Brake Set / Brake Release
F18Sanding Valve13355128
F19Short Air Let Off14363128
F20Compressor730750
F21Slow Spitter Valve1738750
F22N/A
F23N/A
F24N/A
F25N/A
F26N/A
F27N/A
F28N/A